TEMPERED AIR (COMPENSATING)
OVERHEAD GREASE EXHAUST HOODS
Tempered air
(compensating) hoods introduce tempered (heated and/or cooled) or untempered
air into the kitchen independent of other make-up air systems. In most
climates, to maintain a comfortable working temperature in the kitchen,
it will be necessary to heat and/or cool outside air supplied through
a tempered air hood.
STANDARD CONSTRUCTION
Tempered air grease exhaust hoods are constructed of 18 gauge, type
304 stainless steel with a satin polish. All exterior seams are continuously
welded, liquid tight, and are ground and polished to match the original
finish of the material. Supply air is discharged into the kitchen through
extruded aluminum double deflection registers mounted on the front of
and/or bottom of a plenum on the front of the hood. The hoods are UL
and NSF listed, meet the requirements of NFPA 96 and the National Electrical
Code. The hoods include incandescent light fixtures on approximately
3 foot centers wired to a junction box on top of the hood, full length
pitched grease trough with removable grease cup, aluminum baffle type
filters, hanger brackets and factory installed collars and supply air
fire damper if required by UL & NFPA96.
Construction/submittal drawings are available in PDF format, with some drawings in standard (read only) and form (text boxes) format. You will need Acrobat Reader to view and print standard format or Adobe Acrobat to utilize text boxes. Acrobat Reader is available at no charge from the Adobe Website. You will be able to follow the links below to open and view. Use the back arrow to return to this page.
Available Models:
OPTIONS AND ACCESSORIES
Available options include: pitched hood (shorten the front height for
mounting in low ceiling applications; 16 inch minimum front height),
welding hood sections together for single piece construction longer
than 12 (16' maximum single piece length), insulated supply plenum,
perforated face grilles (300T), supply air balancing damper, exhaust
air fire damper, standoff spacer on back of hood (uninsulated or insulated),
fluorescent lights, no lights, stainless steel baffle filters, Flame
Gard filters, loose or mounted switches & pilot lights, 16 or 14
gauge construction, end skirts, back splash (uninsulated or insulated),
top enclosures, finished back on wall hood (wall hood used for a single
island application), painted hood exterior, cabinet on end of hood for
mounting fire suppression hardware and/or controls, and installed fire
protection.
SIZE AVAILABILITY
KS-200T, 300T and 400T hoods are available in a single section in any
increment of length from 4' to 16' (two sections recommended for hoods
over 12' in length). Longer lengths are obtained by butting multiple
sections together utilizing factory supplied welded joint covers. Tempered
air hoods are available in any increment of capture width from 3' to
6' 6". The height for non-pitched hoods can vary in any increment
from 2' to 3', the minimum front height for pitched hoods is 1' 4"
with a minimum back height of 2'.
The KSI-200T, 300T and 400T are two or more wall hoods back to back.
Tempered air hoods are available as single island hoods in a single
section up to 12' long by 8' wide.
TYPICAL SPECIFICATIONS